Bi-level control plastic valve

Description

Hydraulic control valve used to control water level in tanks and reservoirs by means of a differential float valve. When the water reaches the upper preset level the valve closes completely and doesn’t open until the water reaches the lower selected level. This system avoids the frequent starts and stops of the pump getting so to decrease the pumping costs and extending the life of the pump.

Applications

This valve is used to control the maximum and minimum level of water in tanks and reservoirs.

Available models

1 ½”, 2”, 3” BSP (NPT optional)
4” victaulic

Dimensions / Load losses

Download technical PDF

Download PDF technical features and dimensions

Download PDF scheme

Description

References and dimensionss
Product codeValveLHWKg.
892915/4991101 1/2″1881241471,3
892920/4991102″1881241471,3
892930/4991103″2521622092,8
892940/4991104″2952102124,5

(Valves codes with low pressure membrane BP, for high pressure valves with membrane consult AP)

Minimum working pressure
ValveLow PressureHigh Pressure
1″1/20,30,7
2″0,30,7
3″0,50,9
4″0,51,0

 

Head loss, fully opened valve (mca)
Flow (m3/h)
Valve5101520253035404550556065708090100125150
1″1/20,080,350,821,502,403,514,856,428,2210,25
2″0,050,300,601,201,852,803,954,906,107,75
3″0,040,120,250,440,680,971,311,702,132,623,153,734,355,036,518,1810,03
4″0,030,110,220,350,500,680,881,091,331,581,852,132,432,753,424,164,957,159,66
Bold: Advised flow rates