Electrical control plastic valve

Description

This valve opens and closes in response to an electric signal by means of an incorporated 3 way solenoid (3/2). The signal can come from a controller, main switch, PLC, etc.
Depending on the type of the solenoid the valve acts as “NC”, normally closed, which opens when is energized or as “NO”, normally open, which closes when is energized.

Applications

Electrical remote control.
Any application depending on the control device: pressure control, pump protection, flow control, etc.

Available models

1 ½”, 2”, 3” BSP (NPT optional)
4” Victaulic

Dimensions / Load losses

Download technical PDF

Download PDF characteristics and dimensions

Download PDF scheme electrical valve NC

Download PDF scheme electrical valve NO

Description

References and dimensions
Product codeValveLHWKg.
892915/4960451″1/21881241471,2
 892920/4960452″1881241471,2
892930/4960453″2521622092,7
892940/4960454″2952102124,4

(Codes of valves with low presure diaphragm BP, for valves with high pressure diaphragm AP, please consult. 24 VAC solenoid valves NO. Other voltages consult.)

Solenoids
PortWaysFunctionOrificeBody MaterialVoltage*Wires
1/8″”3NO,NC1,2;1,6Reinforced Nylon24 VAC; 9-12 Latch2
1/8″; 1/4″3NO,NC1,2;1,6;2,0Brass24 VAC; 110 VAC; 9-12 Latch2

 

MAXIMUM PRESSURES:

Plastic Body: Protection Class IP66
FunctionOrificeACDCDC Llatch
NC1,211911
1,6656
NO1,2121212
1,6888

 

Brass Body: Protection Class IP65 with connector
FunctionPowerOrifice
1,21,62,0
NCADC201510
AC/8W DC/10W301714
AC/5,5W201510
AC/2,5W DC/5,5W DC/3,5W16109
NOADC201511
AC/8W DC/10W221712
AC/5,5W201511
AC/2,5W DC/3,5W18128

 

Head loss, fully opened valve (mca)
Flow (m3/h)
Válvula5101520253035404550556065708090100125150
1″1/20,080,350,821,502,403,514,856,428,2210,25
2″0,050,300,601,201,852,803,954,906,107,75
3″0,040,120,250,440,680,971,311,702,132,623,153,734,355,036,518,1810,03
4″0,030,110,220,350,500,680,881,091,331,581,852,132,432,753,424,164,957,159,66
Bold: Advised flow rates