Manual control plastic valve

Description

This valve is operated by line pressure by means of a 3 way selector valve, this selector has the positions “open”, “close” and “auto”.
In the “open” position the valve is fully opened, in the “close” position the valve closes slowly to avoid water hammer. “Auto” is used to receive external orders (from solenoid, pressure reducing pilot, etc.)

Aplications

The valve opens and closes in response to a local pressure command.
It is possible to connect the vale to a remote pressure command.

Available models

1 ½”, 2”, 3” BSP (NPT optional)
4” Victaulic

Dimensions / Load losses

Plastic valves dimensions and load losses (E)

Download technical PDF

Download PDF technical features and dimensions

Download PDF scheme

Description

References and dimensions
Product codeValveLHWKg.
892915/4930021″1/21881241471,2
892920/4930022″1881241471,2
892930/4930023″2521622092,7
892940/4930024″2952102124,4

(Valves codes with low pressure membrane BP, for high pressure valves with membrane consult AP)

Minimum working pressure
ValveLow PressureHigh Pressure
1″1/20,30,7
2″0,30,7
3″0,50,9
4″0,51,0

 

Head loss, fully opened valve (mca)
Flow (m3/h)
Valve5101520253035404550556065708090100125150
1″1/20,080,350,821,502,403,514,856,428,2210,25
2″0,050,300,601,201,852,803,954,906,107,75
3″0,040,120,250,440,680,971,311,702,132,623,153,734,355,036,518,1810,03
4″0,030,110,220,350,500,680,881,091,331,581,852,132,432,753,424,164,957,159,66
Bold: Advised flow rates