Pressure reducing plastic valve with electrical control and plastic pilot

Description

Hydraulic control valve used to reduce the inlet pressure to a preset lower level pressure in the outlet by means of a three way plastic reducing pilot incorporated. The control of the valve is done by means of a 3/2 solenoid incorporated. When the solenoid opens the valve it starts to control the outlet pressure and maintains it constant without being affected from upstream flow and pressure variations. The signal might be coming from a Controller, main switch, PLC, etc.
When upstream pressure value is lower than the downstream preset pressure value, the valve opens completely.

Applications

Downstream pressure control.

Available models

1 ½”, 2”, 3” BSP (NPT optional)
4” Victaulic

Dimensions / Pressure loss

Download technical PDF

Download PDF characteristics and dimensions

Download PDF scheme

Description

References and dimensions
Product codeValveLHWKg.
892915/4983051″1/21881291472,0
892920/4983052″1881291472,0
892930/4983053″2521672093,5
892940/4983054″2952152125,2

(Codes of valves with low presure diaphragm BP, for valves with high pressure diaphragm AP, please consult. 24 VAC solenoid valves NO. Other voltages consult.)

Solenoids
ConnexionsWaysFunctionOrificeBody MaterialVoltage*Wires
1/8″”3NO,NC1,2;1,6Reinforced Nylon24 VAC; 9-12 Latch2
1/8″; 1/4″3NO,NC1,2;1,6;2,0Brass24 VAC; 110 VAC; 9-12 Latch2

MAXIMUM PRESSURES:

Plastic Body: Protection Class IP66
FunctionOrificeACDCDC Llatch
NC1,211911
1,6656
NO1,2121212
1,6888

 

Brass Body: Protection Class IP65 with connector
FunctionPowerOrifice
1,21,62,0
NCADC201510
AC/8W DC/10W301714
AC/5,5W201510
AC/2,5W DC/5,5W DC/3,5W16109
NOADC201511
AC/8W DC/10W221712
AC/5,5W201511
AC/2,5W DC/3,5W18128