Electrical control with manual override flanged valve

Description

This valve opens and closes in response to an electric signal by means of an incorporated 3 way solenoid (3/2). The signal cans com from a controller, main switch, PLC, etc. This model also incorporates a 3 way valve for manual operation.
Depending on the type of the solenoid the valve acts as “NC”, normally closed, which opens when is energized, or as “NO”, normally open, which closes when is energized.

Applications

Electric remote control.
Any application depending on the control device: pressure control, pump protection, flow control, etc.
Open and shut off the valve manually independently of the signal received from the remote device.

Available models

DN80 (3”), DN100 (4”), DN125 (5”), DN150 (6”), DN200 (8”), DN250 (10”), DN300 (12”)

Dimensions / Pressure loss

Download technical PDF

Download PDF characteristics and dimensions

Download PDF scheme electrical valve NC

Download PDF scheme electrical valve NO

Description

References and dimensions
Product codeValveLHWKg.
DN80    892335+4960233″27521517215,2
DN100  892345 +4960484″31524020422,2
DN125  892355+4960485″31525520428,4
DN150  892365+4960486″40030030250,4
DN200  892385+4960488″56035030263,4
DN250  892410+49604810″460465372110,6
DN300  892412+49604812″580500372160,6

Codes of valves with high pressure diaphragm AP, for valves with low pressure diaphragm BP, please consult. Valves with 24 VAC NO solenoid. Other voltages, please consult.

Solenoids
PortWaysFunctionOrificeBody MaterialVoltage*Wires
1/8″”3NO,NC1,2;1,6Reinforced Nylon24 VAC; 9-12 Latch2
1/8″; 1/4″3NO,NC1,2;1,6;2,0Brass24 VAC; 110 VAC; 9-12 Latch2

 

MAXIMUM PRESSURES:

Plastic Body: Protection Class IP66
FunctionOrificeACDCDC Llatch
NC1,211911
1,6656
NO1,2121212
1,6888

 

Brass Body: Protection Class IP65 with connector
FunctionPowerOrifice
1,21,62,0
NCADC201510
AC/8W DC/10W301714
AC/5,5W201510
AC/2,5W DC/5,5W DC/3,5W16109
NOADC201511
AC/8W DC/10W221712
AC/5,5W201511
AC/2,5W DC/3,5W18128

 

Minimum working pressure
ValveLow PressureHigh Pressure
DN800,40,7
DN1000,50,7
DN1250,50,7
DN1500,61
DN2000,60,9
DN2500,71,0
DN3000,71,0

 

Head loss, fully opened valve (mca)
Flow (m3/h)
Valve203040506070809010012515020030040050060080010001200
DN800,440,972,623,735,036,518,1810,03
DN1000,350,681,091,582,132,753,424,154,957,159,66
DN1251,001,252,104,559,865,10
DN1501,252,703,758,00
DN2001,002,001,006,008,90
DN2501,652,103,826,10
DN3000,951,322,403,605,10
Bold: Advised flow rates